Tecnológico de Costa Rica
  • How to publish in Repositorio TEC?
  • Policies
  • Educational Resources
  • Contact us
    • español
    • English
  • English 
    • español
    • English
  • Login
View Item 
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Química
  • Licenciatura en Ingeniería Ambiental
  • View Item
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Química
  • Licenciatura en Ingeniería Ambiental
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse

All RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended UserThis CollectionBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended User

My Account

LoginRegister

Statistics

View Usage Statistics

Inventario de gases efecto invernadero de diez instalaciones de una institución pública costarricense

Thumbnail
View/Open
inventario_gases_efecto_inventario_diez_instalacones_institucion_sector.pdf (1.798Mb)
Date
2018
Author
Guadamuz-Arias, Sarita Andrea
Metadata
Show full item record
Abstract
The climate change is a worldwide problem caused primarily by the anthropogenic activities as burning of fossil fuels, and whose consequences generate a negative impact on all living beings in general. In Costa Rica actions are already being taken in order to control it, nevertheless, there are still sectors that have weaknesses in this issue, as it is the case of public institutions which have low compliance in the elaboration of greenhouse gas inventories. Through this project, it was elaborated the inventory of greenhouse gases in the Costa Rican public institution National Institute for Women (INAMU), following the methodology of the national standard INTE B5:2016, subsequently, taking into account the data obtained and observed during visits made to ten of the facilities of the institution, an action plan to reduce the emissions was made, considering the investment costs of the suggested actions, also, improvements were proposed to facilitate the implementation of the action plan proposed to this institution. It was obtained that in 2016 INAMU generated 146,27 ton CO 2 e of which the consumption of electricity and use of vehicles correspond to the sources of greater generation and the central building corresponds to the building with the greatest contribution to the inventory due to being the largest installation. The proposed measures to be implemented in the action plan would reduce 17,57 ton CO 2 e and would generate savings of ₡ 12 765 985,35. In addition, making changes associated mainly with the collection of data records would facilitate the implementation and follow-up process of the proposed action plan.
Description
Proyecto de Graduación (Licenciatura en Ingeniería Ambiental) Instituto Tecnológico de Costa Rica, Escuela de Química, 2018.
URI
https://hdl.handle.net/2238/10089
Share
       
Metrics
Collections
  • Licenciatura en Ingeniería Ambiental [206]

|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1

 

 


|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1