Tecnológico de Costa Rica
  • How to publish in Repositorio TEC?
  • Policies
  • Educational Resources
  • Contact us
    • español
    • English
  • English 
    • español
    • English
  • Login
View Item 
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Biología
  • Licenciatura en Ingeniería en Biotecnología
  • View Item
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Biología
  • Licenciatura en Ingeniería en Biotecnología
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse

All RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended UserThis CollectionBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended User

My Account

LoginRegister

Statistics

View Usage Statistics

Evaluación de homogeneidad y estabilidad de anticuerpos IgG anti Trypanosoma Cruzi en muestras de suero sanguíneo empleadas como ítem de ensayo del programa de evaluación externa del desempeño del Tamizaje de la enfermedad de Chagas.

Thumbnail
View/Open
evaluacion_homogeneidad_estabilidad_anticuerpos_IgG_ anti_trypanosoma_cruzi_muestra_suero_sanguineo_empleadas_item_ensayo_programa_evaluación_externa_desempeño_tamizaje_enfermedad_chagas.pdf (800.8Kb)
Date
2018
Author
Chavez-Gutierrez, Mariel
Metadata
Show full item record
Abstract
Chagas disease is an American continent endemic illness, caused by the protozoan Trypanosoma cruzi. Diagnosis is mainly based upon serologic methodologies such as Chemiluminescent Microparticle Immunoassay (CMIA), which is employed in Costa Rica for donated blood screening. In order to perform a continuous monitoring of blood banks performance, the Chagas Disease Screening Evaluation Program proficiency test has been established. The objective of the present investigation was to assess the homogeneity and stability of proficiency test items according to INTE-ISO/IEC 17043:2010 standard. For that purpose fulfillment, experimental designs and testing methods were carried out following INTE/ISO 13528:2016 standard guidelines. In quantitative terms, it was determined that the analyzed sera had some heterogeneity degree, as well as insufficient stability regarding the analyte of interest which corresponds to IgG class anti-T. cruzi antibodies. Given the qualitative nature of ARCHITECT Chagas immunoassay and the fact that the samples demonstrated no significant reactivity changes, the proficiency test items were accepted as suitable for evaluation of participant performance.
Description
Proyecto de Graduación (Licenciatura en Ingeniería en Biotecnología) Instituto Tecnológico de Costa Rica, Escuela de Biología, 2018.
URI
https://hdl.handle.net/2238/10340
Share
       
Metrics
Collections
  • Licenciatura en Ingeniería en Biotecnología [10]

|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1

 

 


|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1