Tecnológico de Costa Rica
  • How to publish in Repositorio TEC?
  • Policies
  • Educational Resources
  • Contact us
    • español
    • English
  • English 
    • español
    • English
  • Login
View Item 
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Ingeniería Electromecánica
  • Licenciatura en Mantenimiento Industrial
  • View Item
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Ingeniería Electromecánica
  • Licenciatura en Mantenimiento Industrial
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse

All RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended UserThis CollectionBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended User

My Account

LoginRegister

Statistics

View Usage Statistics

Diseño de puesta a tierra y sistemas de protección de pararrayos para una planta fotovoltaica de 500kW en la sede central del Tecnológico de Costa Rica

Thumbnail
View/Open
Diseño_puesta_tierra_sistemas_proteccion_pararrayos_planta_fotovoltaica.pdf (2.139Mb)
Date
2017
Author
Mena-Cerdas, Brayan Gerardo
Metadata
Show full item record
Abstract
The concept of grounding refers to the intentional electrical connection with the earth, either from a part of the circuit (system grounding) or from metal parts that do not belong directly to it (equipment grounding). These ground connections must be sufficiently low impedance and ampacity to prevent the formation of dangerous voltages for people or connected equipment and to provide a path for the earth fault current to flow, Facilitate the operation of the protection devices to release the fault. On the other hand, lightning arrester systems must be capable of safely conducting ground current from lightning. The objective of the present work was to design the grounding system and lightning rods for a 500 kW solar complex located at the headquarters of the Technological Institute of Costa Rica. In addition, the development of a grounding guide for photovoltaic systems in the country. To achieve this, the design was based and adapted from the IEEE 80 standard, which corresponds to the design of grounding for alternating current substations. The fundamental parameters for obtaining ground designs are the ground resistivity and the maximum fault current. The first was measured with the Wenner method with a value of 98.65 Ωm and the second was determined for the system as the short-circuit current for the PV array that was larger, in this case 103 A. The voltages of touch and step, where the maximum permissible values were 104.06 V and 144.30 V respectively. The theoretically obtained design will have a resistance of 0.80 Ω, which is less than the 1 Ω value allowed by the standard. The lightning arrestor system was selected with the deionizing technology, since it offers greater security.
Description
Proyecto de Graduación (Licenciatura en Ingeniería en Mantenimiento Industrial) Instituto Tecnológico de Costa Rica. Escuela de Ingeniería Electromecánica, 2017.
URI
https://hdl.handle.net/2238/7363
Share
       
Metrics
Collections
  • Licenciatura en Mantenimiento Industrial [286]

|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1

 

 


|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1