Mostrar el registro sencillo del ítem
Estudio de remoción de arsénico en agua potable a nivel domiciliar mediante oxidación solar y coagulación-floculación
Study of arsenic removal in drinking water at household level using solar oxidation and coagulation-flocculation techniques
dc.contributor | es-ES | |
dc.contributor | en-US | |
dc.creator | Rojas-Chaves, Paola | |
dc.creator | Vargas-Benavides, María J. | |
dc.creator | Araya-Obando, Andrés | |
dc.creator | Valverde-Cerdas, Johnny | |
dc.creator | Romero-Esquivel, Luis Guillermo | |
dc.date | 2015-12-11 | |
dc.date.accessioned | 2017-09-19T20:37:38Z | |
dc.date.available | 2017-09-19T20:37:38Z | |
dc.identifier | https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/2443 | |
dc.identifier | 10.18845/tm.v28i4.2443 | |
dc.identifier.uri | https://hdl.handle.net/2238/8748 | |
dc.description | En Costa Rica, a pesar de que se han hecho esfuerzos por abastecer de agua segura a las comunidades afectadas por la presencia de arsénico en el líquido, una parte de la población aún se encuentra expuesta, posiblemente debido a que no están conectadas a una red de acueductos. Es por ello que en este estudio se presentan dos soluciones a nivel domiciliar para eliminar el arsénico: una por oxidación solar (SORAS) y otra por un proceso de coagulación-floculación. En ambos casos, el arsénico es removido por adsorción o coprecipitación sobre los óxidos hidróxidos de hierro (III) formados. En el sistema SORAS se encontró que para reducir la concentración de arsénico de 200μg/L a menos de la norma (10μg/L), se necesitan entre 2h y 4h de exposición en un día soleado o nublado, respectivamente. En el sistema de coagulación-floculación, las condiciones óptimas para obtener niveles de arsénico por debajo de la norma fueron las siguientes: con floculante sintético, el pH fue 6 con 1 mg/L de FK-930-S (polímero de cloruro de polidialil-dimetilamonio) con dosis de FeCl3 12 mg/L; con floculante natural, el pH fue 6 con 250 mg/L de mozote (Triumfetta semitriloba), con dosis de FeCl3 de 14 mg/L. Un prototipo consistente en un recipiente de coagulación-fluculación y otro de filtración en arena fue capaz de tratar 15 L de agua sintética con 200μg/L As y agua natural con 10 y 50μg/L. A pesar de estos resultados, es necesario evaluar ambas técnicas en las comunidades, incluyendo aspectos de capacitación y aceptación. | es-ES |
dc.description | In Costa Rica, even though there have been efforts to provide safe water to communities affected by the presence of arsenic, there is a part of the population still exposed because might not be connected to a network of aqueducts. Two solutions household level use for As reduction are presented: one is the solar radiation oxidation (SORAS) and second one is the flocculation - coagulation process. Both solutions showed reduced As concentration due to adsorption or co-precipitation on the iron (III) oxide hydroxides. The SORAS system needed 2h and 4h of exposure in a sunny or cloudy day respectively to reduce the arsenic concentration from 200μg / L to less than the standard (10 ug / L). For coagulation - flocculation system, best conditions were achieved at pH 6 with synthetic flocculant FK-930-S (polymer polydiallyl-dimethylammonium chloride) at 1 mg/L dose and FeCl3 12 mg/L dose; for natural flocculant it was achieved at pH 6 with mozote (Triumfetta semitriloba) at 250 mg/L dose, and FeCl3 14 mg/L dose. A prototype consisting in a coagulation-flocculation container and a sand filtration step was able to treat 15 liters of synthetic water with 200μg / L As and natural water with 10 and 50 ug / L. Despite these results, it is necessary to evaluate both techniques in communities, including aspects of training and acceptance. | en-US |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Editorial Tecnológica de Costa Rica | es-ES |
dc.relation | https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/2443/2229 | |
dc.rights | Copyright (c) 2015 Revista Tecnología en Marcha | es-ES |
dc.source | Revista Tecnología en Marcha; Vol. 28, Núm. 4: Octubre-Diciembre 2015; pág. 54-65 | es-ES |
dc.source | 2215-3241 | |
dc.source | 0379-3982 | |
dc.subject | es-ES | |
dc.subject | Agua de consumo humano; remoción de arsénico; oxidación solar; floculación; coagulación. | es-ES |
dc.subject | en-US | |
dc.subject | Drinking water; arsenic removal; solar oxidation; flocculation; coagulation. | en-US |
dc.title | Estudio de remoción de arsénico en agua potable a nivel domiciliar mediante oxidación solar y coagulación-floculación | es-ES |
dc.title | Study of arsenic removal in drinking water at household level using solar oxidation and coagulation-flocculation techniques | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | Artículo revisado por pares | es-ES |
dc.type | es-ES | |
dc.type | en-US |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tecnología en Marcha [2043]
Es una revista que se publica por trimestres