Mostrar el registro sencillo del ítem
Propuesta de programa de mejora de las condiciones de accesibilidad del entorno físico para los edificios SJ-01, SJ-02 y SJ-06 del Campus Tecnológico Local San José
dc.contributor.advisor | Campos-Fumero, Adriana | es |
dc.contributor.author | Vega-Redondo, Franciny | |
dc.date.accessioned | 2021-09-21T19:08:07Z | |
dc.date.available | 2021-09-21T19:08:07Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | https://hdl.handle.net/2238/13339 | |
dc.description | Proyecto de Graduación (Licenciatura en Ingeniería en Seguridad Laboral e Higiene Ambiental) Instituto Tecnológico de Costa Rica, Escuela de Ingeniería en Seguridad Laboral e Higiene Ambiental, 2021 | es |
dc.description | Esta tesis cumple con el Objetivo ODS 11 de la Agenda 2030 “lograr que las ciudades y los asentamientos humanos sean inclusivos, seguros, resilientes y sostenibles”, con la meta número 7: “Proporcionar acceso universal a zonas verdes y espacios públicos seguros, inclusivos y accesibles, en particular para las mujeres y los niños, las personas de edad y las personas con discapacidad". | |
dc.description.abstract | El siguiente estudio se desarrolla con el objetivo de diseñar una propuesta de programa de mejora de las condiciones de accesibilidad al entorno físico en los edificios SJ-01, SJ-02 y SJ-06 del Campus Tecnológico Local San José, ubicado en Barrio Amón. Se basa en los objetivos de identificar las condiciones existentes, evaluar el cumplimiento en cuanto a accesibilidad al entorno físico según la legislación y proponer alternativas de solución para asegurar el cumplimiento de las condiciones de accesibilidad al entorno físico en los edificios evaluados. Este documento incluye una etapa de diagnóstico donde se registran las condiciones actuales mediante la recolección de datos con listas basadas en la información de la lista de verificación contenida en la Guía Integrada para la Verificación de la Accesibilidad al Entorno Físico, posteriormente se elaboran matrices de cumplimiento e incumplimiento para calcular porcentajes. Basado en los porcentajes mencionados se establece una razón de cálculo que asignará una nota o puntaje de cumplimiento para cada edificio. Del ejercicio de análisis mencionado se identifica el SJ-06 como el edificio de mayor cumplimiento, con una nota de 76.08, y por lo tanto de mayor accesibilidad según los aspectos evaluados; seguido el SJ-02 con 75.5 y el SJ-01 con 70.91. Se concluye de los edificios evaluados el SJ-06 es el más accesible, sin embargo, hay incumplimientos que se debieron prever desde su diseño siendo el de construcción más reciente. Se identifica la señalización como el componente con menor cumplimiento en los tres edificios. Dentro de las alternativas de mejora se tienen tres propuestas que incluyen la solución a todos los incumplimientos, así como tres alternativas a la falta de medios de egreso del SJ-01. | es |
dc.description.abstract | The following study is developed to create a program to improve accessibility conditions to the physical environment in buildings SJ-01, SJ-02, and SJ-06 of the Campus for the Instituto Tecnologico de Costa Rica (ITEC), located in Barrio Amón, San Jose. It is based on the objectives of identifying the existing conditions, evaluating compliance in terms of accessibility to the physical environment according to the legislation, and proposing alternative solutions to ensure compliance with the conditions of accessibility to the physical environment in the buildings evaluated. This document includes a diagnostic stage where current conditions are recorded by collecting data with lists based on the information from the checklist contained in the Integrated Guide for Verification of Accessibility to the Physical Environment, followed by compliance matrices, and failure to calculate percentages. Based on the percentages mentioned, a calculation reason is established to assign a grade or compliance score for each building. From the aforementioned analysis exercise, SJ-06 is identified as the building with the highest compliance, with a score of 76.08, and therefore with the highest accessibility according to the aspects evaluated; followed by SJ-02 with 75.5 and SJ-01 with 70.91. It is concluded of the evaluated buildings the SJ-06 is the most accessible, however, some non-compliances should have been anticipated from its design being the most recent construction. Signage is identified as the component with the lowest compliance in the three buildings. Among the alternatives for improvement, three proposals include the solution to all non-compliances, as well as three alternatives to the lack of means of egress from SJ-01. | es |
dc.language.iso | spa | es |
dc.publisher | Instituto Tecnológico de Costa Rica | es |
dc.rights | acceso abierto | * |
dc.rights.uri | http://creativecommons.org/licenses/by-sa/4.0/ | * |
dc.subject | Accesibilidad | es |
dc.subject | Ley 7600 | es |
dc.subject | Discapacidad | es |
dc.subject | Señalización | es |
dc.subject | Espacios físicos | es |
dc.subject | Instituciones de educación superior | es |
dc.subject | Remodelaciones | es |
dc.subject | Edificios accesibles | es |
dc.subject | Condiciones de accesibilidad | es |
dc.subject | Accessibility | es |
dc.subject | Disability | es |
dc.subject | Signaling | es |
dc.subject | Physical spaces | es |
dc.subject | Higher education institutions | es |
dc.subject | Remodeling | es |
dc.subject | Accessible buildings | es |
dc.subject | Accessibility conditions | es |
dc.subject | Research Subject Categories::TECHNOLOGY::Civil engineering and architecture | es |
dc.title | Propuesta de programa de mejora de las condiciones de accesibilidad del entorno físico para los edificios SJ-01, SJ-02 y SJ-06 del Campus Tecnológico Local San José | es |
dc.type | tesis de licenciatura | es |