Tecnológico de Costa Rica
  • How to publish in Repositorio TEC?
  • Policies
  • Educational Resources
  • Contact us
    • español
    • English
  • English 
    • español
    • English
  • Login
View Item 
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Ingeniería en Construcción
  • Licenciatura en Ingeniería en Construcción
  • View Item
  •   Repository Home
  • Trabajos de Graduación
  • Biblioteca José Figueres Ferrer
  • Escuela de Ingeniería en Construcción
  • Licenciatura en Ingeniería en Construcción
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse

All RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended UserThis CollectionBy Issue DateAuthorsTitlesKeywordEducational Resource TypeIntended User

My Account

LoginRegister

Statistics

View Usage Statistics

Evaluación de los Métodos para el Cálculo de Caudales Máximos Probables instantáneos en Edificaciones

Thumbnail
View/Open
evaluaciondelosmetodosparaelcalculodecaudalesmaximos.pdf (1.486Mb)
Date
2013
Author
Zamora-Álvarez, Renán Alonso
Metadata
Show full item record
Abstract
The design methodologies of the probable max flow in buildings is based on empirical, half empirical and probabilistic subsistence, most of them estimated long time ago with high intake health hardware, what makes its implementation today involve in most of the cases an over estimation of the estimated volume making more expensive the designs of the internal edifications. The present work evaluated eight theoretical methods which contrasted with the probable max caudal graduated in four buildings using a Innova Sonic 210-I ultrasonic flow measurer. The research contemplates the measurements of volume of an offices building, a school, an apartment building, and in a house-room. In addition, is made a comparison of the intake reported for the health hardware in the theoretical models and the gauging done on each one of the hardware installed on the edifications. It was obtained that the French Norm and Hunter Colombia methods are the ones who generated the closest values graduated on an error percentage of 6.9% and 5.5% in the case of Hunter Colombia for the school and the apartment building respectively and a 5.9% and 15.5% for the houseroom and the offices building reported by the French Norm. The health hardware that are actually on the market differ on the spending values in liters/ second, respect to the normed values in the theoretical methodologies, with a mistake percent that goes from the 30% to a 75% average. This research is a base for cementing the future investigations that allow the compilation of enough information to obtain more general results respect to the max probable flow and the variation on the time demand.
Description
Proyecto de Graduación (Licenciatura en Ingeniería en Construcción).Instituto Tecnológico de Costa Rica. Escuela de Ingeniería en Construcción, 2013.
URI
https://hdl.handle.net/2238/6203
Share
       
Metrics
Collections
  • Licenciatura en Ingeniería en Construcción [553]

|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1

 

 


|Contact us

Repositorio Institucional del Tecnológico de Costa Rica

Sistema de Bibliotecas del TEC | SIBITEC

© DERECHOS RESERVADOS. Un sitio soportado por DSpace(v. 6.3)

RT-1