dc.description.abstractIn this specialty practice, it has developed a project that consists of two parts, both related. The technical part is in the mechanical area, more specifically in the area of thermal fluids and the other part is maintenance management. The technical part is calculating thermal load for air conditioning supply clinical laboratory, belonging to Maximiliano Peralta Jiménez Hospital, located in the central region of the province of Cartago. To start calculating thermal load several views of the enclosure were made to carry out a survey of the most important laboratory data such as building materials, electrical grid, space available, internal temperature, teams in each venue, number of people they are working in each enclosure and a check of air conditioning equipment currently installed. He proceeded to perform calculations based on ASHRAE, specifically in the volumes of ASHRAE Handbook HVAC design fundamentals and Manual for Hospital and Clinics. Enclosures have studied two are only installed ventilation, both extraction and injection of fresh air, this will be based on the national standard INTE 31-08-08-03. After calculating the thermal load, we proceeded to select the team, designing products, based on criteria of flow, sound and conduction losses air. Enclosures studied This was proposed a design that allows air conditioning make a budget to serve in receiving offers from different providers of air conditioning equipment. The administrative part is to make plans and preventive maintenance routines for air conditioning equipment and selected for the clinical laboratory ventilation. Finally, a financial analysis of the project will be madees
dc.description.sponsorshipBenemérito Hospital Dr. Maximiliano Peralta Jiménez-CCSSes
dc.language.isospaes
dc.publisherInstituto Tecnológico de Costa Ricaes
dc.subjectVentilaciónes
dc.subjectMantenimiento preventivoes
dc.subjectAdministraciónes
dc.subjectMecánicaes
dc.subjectTemperaturaes
dc.subjectEquipoes
dc.subjectResearch Subject Categories::TECHNOLOGY::Engineering mechanics::Mechanical and thermal engineeringes
dc.titleCálculo de carga térmica para el suministro de aire acondicionado del laboratorio clínico y planes de mantenimiento preventivo para equipo de aire acondicionado clínico, Hospital Dr. Maximiliano Peralta Jiménez.es
dc.typelicentiateThesises


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record